Une histoire de succès
Vous êtes ici
Accueil » Sterilight
Sterilight
Message d'erreur
- Notice : Trying to access array offset on value of type int dans element_children() (ligne 6527 dans /home2/saimexdz/public_html/includes/common.inc).
- Notice : Trying to access array offset on value of type int dans element_children() (ligne 6527 dans /home2/saimexdz/public_html/includes/common.inc).
- Notice : Trying to access array offset on value of type int dans element_children() (ligne 6527 dans /home2/saimexdz/public_html/includes/common.inc).
- Deprecated function : implode(): Passing glue string after array is deprecated. Swap the parameters dans drupal_get_feeds() (ligne 394 dans /home2/saimexdz/public_html/includes/common.inc).
- Deprecated function : The each() function is deprecated. This message will be suppressed on further calls dans menu_set_active_trail() (ligne 2396 dans /home2/saimexdz/public_html/includes/menu.inc).
Sterilight
UV/Ozone
Sterilight SM80
Application: Light Commerical
Flow Rate: 80 USGPM (303 lpm)
Inlet/outlet port size: 2” MNPT
Electrical: 120 V
Sensor: Yes
Validated: No
SV50 | S80 | SM80 | ||
---|---|---|---|---|
Flow Rate (85% UVT eol) |
VIQUA Standard (30mJ/cm²) |
0.0 lpm (0.0 gpm) (0.0 m³/Hr) |
303.0 lpm (80.0 gpm) (18.2 m³/Hr) |
303.0 lpm (80.0 gpm) (18.2 m³/Hr) |
NSF/EPA (40mJ/cm²) |
189.3 lpm (50.0 gpm) (11.4 m³/Hr) |
0.0 lpm (0.0 gpm) (0.0 m³/Hr) |
0.0 lpm (0.0 gpm) (0.0 m³/Hr) |
|
Dimensions | Length |
103.0 cm (40.6 ") |
103.0 cm (40.6 ") |
103.0 cm (40.6 ") |
Diameter |
10.0 cm (3.9 ") |
10.0 cm (3.9 ") |
10.0 cm (3.9 ") |
|
Controller |
33 x 16.5 cm (13" x 6.5") |
33 x 16.5 cm (13" x 6.5") |
33 x 16.5 cm (13" x 6.5") |
|
Inlet/Outlet Port Size | 2" MNPT | 2" MNPT | 2" MNPT | |
Shipping Weight |
6.4 kg (14.1 lbs) |
6.4 kg (14.1 lbs) |
6.4 kg (14.1 lbs) |
|
Electrical | Volts |
100-240V 50-60Hz |
100-240V 50-60Hz |
100-240V 50-60Hz |
Max. current | 2.4 Amp | 2.4 Amp | 2.4 Amp | |
Power Consumption | 230 W | 230 W | 230 W | |
Lamp Power | 200 W | 200 W | 200 W | |
Operating Parameters | Maximum Operating Pressure |
100 PSI (689 kPa) |
100 PSI (689 kPa) |
100 PSI (689 kPa) |
Ambient Temperature |
2-40 °C (36-104 °F) |
2-40 °C (36-104 °F) |
2-40 °C (36-104 °F) |
|
Visual "Power On" | Yes | Yes | Yes | |
Reactor Chamber Material | 316L S.S. | 316L S.S. | 316L S.S. | |
UV Intensity Monitor | Yes | No | Yes | |
Validation | USEPA UVDGM validation protocol | N/A | N/A | |
Colour-coded plug and play connections | Yes | Yes | Yes | |
CoolTouch fan | Yes | Yes | Yes | |
Communications ports (two, RJ45) | Yes | Yes | Yes | |
Controls | Audible alarm mute button | Yes | Yes | Yes |
Lamp age indicator | Yes | Yes | Yes | |
Lamp operation indicator | Yes | Yes | Yes | |
Ballast operation idicator | Yes | Yes | Yes | |
Solenoid operation indicator | Yes | Yes | Yes | |
Fan operation indicator | Yes | Yes | Yes | |
Sensor reading indicator | Yes | No | Yes |